Home  l Sitemap l English
logo
line
home products&how to use company profile Q&A links
line
Home   >   Uses and introduction of products   >   The seismic sensors VIBRA ACE(electrical type)
V-012P-F
V-012P


   <<Based on The Elevator Technical Standards
                   2009 edition formed by Ministy of Land,
                                    Infrastructure and Transpart>>

    
 Seismic Sensor only for preliminary tremor.
   
    ・Compact and slim type.
        ・Complete the high reliability with original logic.
        ・High/Low accele changing on-site..
        ・Waterproof type as optional.(IP 67)

   
Model
     VIBRA ACE    V-012P-F
Detection Method
     Electrostatic Capacitance Electronic Sensor
External Dimensions
     150(W)×200(H)×60(D)  mm
Weight
     Approx. 0.8kg
Acceleration Setting

     2.5gal (High Sensitivity) 5gal (Low Sensitivity) or
           5gal (High Sensitivity)  10gal (Low Sensitivity)
         (The gal is set before shipping.)
                 ⇒The seismic intensity scale and acceleration

Detection Contact
     1a (dry contact)
Reset method

     Automatic Reset
     The retention time of operation signal is set within
     the range from 10 seconds to 60 seconds.
     (The gal is set before shipping.)

Detection direction
     Vertical direction. (Use only for P - Wave)
Usages

     ・Control for elevator and others.
     ・Reliability increases by being linked linked to
       the real-time earthquake information.